6.2.2.2 RLink JTAG-SWD ADP jumpers
When using a stand-alone RLink, you must use an ADP to adapt the RLink’s 24-pins connector to the
target connector. If using JTAG-ARM ADP, there is no configuration to perform. If using JTAG-SWD
ADP, you must plug two jumpers on the left side, as shown in the picture (default factory setting).
Note: SWD is supported by this version of the software. There is no need to change the jumpers
position, keep them in the positions shown in this picture. (JTAG) As the SWD connector is a subset of
the JTAG connector, you can also use the SWD protocol with the older JTAG-ARM ADPs, and also with
all versions of the REva board.