User manual
Raisecom Technology Co., Ltd
9
ON Enable
z 6
th
bit: setting for Ethernet data frame length
6
th
bit Ethernet data frame length setting
ON 1916 byte
OFF 1536 byte
8 bit DIP-Switches on right side:
z If auto-negotiation on from 1
st
through 4
th
Ethernet port, set duplex mode.
Note: supports 10/100Mbps auto-adaptive Ethernet port and full/half duplex
auto-negotiation.
Auto-negotiation fail: set duplex mode of port referring to the 4bits switches
Auto-negotiation success: working on full duplex mode foreign to 4 bits switches setting.
Definition
1
st
2
nd
3
rd
4
th
OFF Full duplex OFF Full duplex OFF Full duplex OFF Full duplex
ON Half duplex ON Half duplex ON Half duplex ON Half duplex
z The 5
th
and 6
th
bit of Ethernet port: enable or disable insulation function of Ethernet port
5
th
6
th
Definition
OFF OFF 1~4 can communicate each other, default setting
OFF ON 1~4 Ethernet port isolated on local end
ON OFF 1~4 port isolated oppositely both on two sides
(with TAG)
ON ON 1~4 port isolated oppositely both on two sides
(without TAG)
‘Communicate’ means all users at 4 Ethernet ports of local end can communicate either each
other or with users at remote end.
“Isolated on local end” means users, at 4 Ethernet ports of local end, isolate each other; but can
communicate with users at remote end.
“isolated oppositely on two sides” means the 1
st
port of local end can communicate with the 1
st
port of remote end, the 2
nd
port of local end can communicate with the 2
nd
port of remote end, the
3
rd
port of local end can communicate with the 3
rd
port of remote end and the 4
th
port of local end
can communicate with the 4
th
port of remote end. Whether add TAG target or not as per users’
requirement. If enable this function, require to configure both ends to “isolated oppositely
on two sides” simultaneously.
z 7
th
bit: NM control RS232/485 selectable switch
7
th
NM control selection
OFF RS232 control
ON RS485 control
If connect NM port of connection device LINKUP with computer serial port, whether use