4. How to use
4.1. Introduction of the Front Panel
The front panel includes the indications of E1 receiving signal loss alarms and optical
alarms. All the alarms are for the receiving link (signal input). The Line L indicates the
alarms generated at the local site and Line R at the remote site. The remote alarms are
sent through the optical link, so that they are accurate only when the optical receiving is
Power (Green), ON when works properly
E1 LOS alarms (Red): ON when loss of signal in E1 channels
LOS optical alarm (Red): ON when loss of signal in optical link
ERR alarm (Yellow): ON when receiving error occurs. The
detailed alarm reasons, including LOF, 10
-3
BER, and 10
-6
BE
R
can be viewed in network management software.
Fiber connector: DSC/PC for dual-strand fiber, TX for transmit and RX
for receive; SC/PC for single strand fiber
Mask fake alarm button:
Push-in, mask E1 fake alarms; push out, unmask.
Valid for both Unit 1 and Unit 2
Figure 1. Sketch of RC802-120B*2, RC804-120B*2 front panel
L line indicates local alarms, R for remote alarms
Fixing Handle
Fixing Handle
First Unit
Second Unit. The definitions are the same as the
first unit.