User manual

Raisecom Technology Co., Ltd
15
OFF Disable
To make local timeslot follow remote timeslot, below three conditions should be ensured:
(1) This series device is used point to point in pair.
(2) There is no PCM device which occupy the Sa bit linked in E1 line.
(3) Local device works on slave clock mode.
When all of above condition is satisfied, setting the SW5-3 of local device as ON to open
timeslot auto-follow function, the timeslot and frame mode (PCM30/PCM31) of local
device will follow the configurations of remote device automatically.
3. The 4
th
bit: Error code test function choosing dip-switch BET (default OFF)
SW5-4 Internal Error Code Test Function
ON Enable
OFF Disable
There is an error code test unit inside this series device, and the main purpose of this unit
is producing pseudo random sequence (2E15-1 STD) and sending them to optical line.
This sequence can be uploaded to proper data channel by configuration, and then via
many loopback modes the returned sequence is sent to device for testing. The testing
result will be displayed by the PWR/PAT indicator on front panel. When error code is
captured the PWR/PAT indicator will turn to green and keep for at least one second. If
there is no new error code occurs the PWR/PAT indicator will come back to steady yellow
status.
The device will add test sequence to user data channel after the error code test function is
enabled. This function is available in fractional mode and unframed (transparent) mode,
and when this function is enabled the V.35 operation will intermit.
Notice: The error code test function can be operated with many loop back tests. When the
local bidirectional loop back function is disabled the loop back can be simulated by fiber,
but the dual-fiber S3 and all single fiber device can not. At the time if PWR/PAT indicator is
steady yellow, it indicates that correct test code was received. If the remote bidirectional
loop back is enabled accompanied with error code test, it means the whole information
process will be tested.
4. The 5
th
bit: V.35 RX CLK Phase Choosing Dip-switch (default OFF)
SW5-5 Phase Choosing
ON RX CLK Reverse Phase
OFF RX CLK Positive Phase
The RX CLK phase choosing is provided because of the different V.35 clock and data
phase of different brand router. On Cisco series router the test result of V.35