before power on! If the switches are configured during running status, the device
must be restarted to make the configuration effective. Each dip-switch is shown as the
left figure. The DOWN indicates OFF and UP indicates ON when from left to right the bit is
1
st
to 8
th
. There is also a note pasted on the bottom of the device as the following figure:
Configuration Note on the device bottom
4.3.1. Setup of Timeslot Dip-switch (SW1 to SW4)
Timeslot switches are SW1, SW2, SW3 and SW4.
“√” indicates enable; “×” indicates disable
SW1 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET Frame Status TS1 TS2 TS3 TS4 TS5 TS6 TS7
ON Fractional √ √ √ √ √ √ √
OFF Unframed × × × × × × ×
SW2 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15
ON √ √ √ √ √ √ √ √
OFF × × × × × × × ×
SW3 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
S
W1 SW2 SW3 SW4 SW5 SW6
O
ptic
Port
V
.35 Port
Power
Interface
Power
Switch