RC801-30B-FV35, RC803-30B-FV35, RC805-30B-FV35 Series Standalone V.35 Interface Fiber Optic Modem User Manual REV.N Raisecom Technology Co., Ltd.
Raisecom Technology Co., Ltd 1. Cautions Please read the following notices carefully before installing and using the device. Raisecom does not respond to any loss that caused by violating safety notice. RC801/803/805-30B-FV35 series device provides V.35 synchronization data interface which complied with ITU standard. Please firstly connect the V.35 cable before the device power on. It is seriously forbidden to insert or pull out V.
Raisecom Technology Co., Ltd Contents 1. Cautions.................................................................................................................... 1 2. Overview ................................................................................................................... 4 2.1. 2.2. 2.3. 3. Parameters ............................................................................................................... 7 3.1. 3.2. 3.3. 3.4. 3.5. 3.6. 4. Introduction .................
Raisecom Technology Co., Ltd 1. 2. CBL-V35-M34M/M34F-D Cable making Instruction ............................................. 23 CBL-V35-M34M/M34M-X-D Cable making Instruction .........................................
Raisecom Technology Co., Ltd 2. Overview 2.1. Introduction RC801/803/805-30B-FV35 series device is PDH fiber optic modem which is deployed to transmit V.35 signals and transparent E1 data line on fiber. It also provides solution for Router remote connection and is widely used in constructing Wide Area Networks. RC801/803/805-30B-FV35 series device is standalone dual interface fiber optic modem which can be placed on desktop and has individual power supply.
Raisecom Technology Co., Ltd 2.3. Model Description RC800-30B-FV35 series fiber optic modem includes the following types: Model Type RC801-30B-FV35-S1(AC) Description Standalone at the Customer Premises, one V.35 interface(M 34), one Optical interface, SM Dual strand(DSC),0-25km, AC RC801-30B-FV35-S1(DC) Standalone at the Customer Premises, one V.35 interface(M 34), one Optical interface, SM Dual strand(DSC),0-25km, DC RC801-30B-FV35-S2(AC) Standalone at the Customer Premises, one V.
Raisecom Technology Co., Ltd RC804-30B-FV35-S2 RC806-30B-FV35-S1 RC806-30B-FV35-S2 Module at central office, one V.35 interface (HDB 26 male ), one optical port, single fiber single mode 1310 (SC-APC), 10-50Km Customer premises module, one V.35 interface (HDB 26 male ), one optical port, single fiber single mode 1550 (SC-PC), 0-25Km Customer premises module, one V.
Raisecom Technology Co., Ltd 3. Parameters 3.1. V.35 Interface Specification Physical Characteristics: Connector Type: Working Mode: Interface Bit Rate: Complies with V.35 interface standard of ITU suggestions ISO2593 female connector (M 34 interface) DCE (support cross connection with other DCE device) V.35 interface bit rate is N×64Kbps(N=1~31)at E1 fractional mode; V.35 interface bit rate is 2048Kbps at E1 transparent mode 3.2.
Raisecom Technology Co., Ltd 3.4. Power Supply & Power Consumption Power Supply: DC –48V, tolerance range is from –36V to –72V DC +24V, tolerance range is from +18 V to +36V AC 220V, tolerance range is from 165V to 265V Power Consumption: ≤ 5W 3.5. Dimensions Standalone equipment can be placed on the table. Dimension: 142 (width) x 38 (height) x 187 (depth) mm 3.6.
Raisecom Technology Co., Ltd 4. How to Use 4.1. Description of the Front Panel RC800-30B-FV35 SERIES V35 LOS PWR/PAT TX RX LOF TD LOF AIS ERR CRC LOOP RD View of the front panel 4.1.1. Power Supply/Error Code Test Indicator PWR/PAT Green/Yellow: Steady Green, built-in power works in good condition. Yellow, when using built-in error code test function, if the fiber interface receives its own sending pseudo random sequence data the indicator will be in steady yellow.
Raisecom Technology Co., Ltd 4.1.3. V.
Raisecom Technology Co., Ltd the contrary, if there is no CRC4 checkout signal in E1 data of optical interface the CRC4 checkout function will be disable and CRC alarm indicator unavailable. 4.1.4. Fiber Interface For RC801-30B-FV35 dual strand device, TX stands for optical signal output (transmit) and RX stands for input (Receive). For RC803/5-30B-FV35 single strand device, TX and RX has no actual meanings. In one fiber the transmission and receiving can be distinguished by different wave length. 4.2.
Raisecom Technology Co., Ltd connect the grounding end on the right of the device to the protection grounding of the center office. DC Power connector: It has three connection end: -48V, PGND and BGND. Please make sure that the PGND end is connected to protection grounding. The grounding end on the right of the device and the PGND are internally connected, so it is enough to connect any of it to protection grounding. 4.2.3. V.35 Connector Left figure is a standard ISO2593 connector of V.35 interface.
Raisecom Technology Co., Ltd before power on! If the switches are configured during running status, the device must be restarted to make the configuration effective. Each dip-switch is shown as the left figure. The DOWN indicates OFF and UP indicates ON when from left to right the bit is 1st to 8th. There is also a note pasted on the bottom of the device as the following figure: SW1 V.35 Port SW2 SW3 SW4 SW5 Optic Port SW6 Power Interface Power Switch Configuration Note on the device bottom 4.3.
Raisecom Technology Co., Ltd SET TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23 ON √ √ √ √ √ √ √ √ OFF × × × × × × × × SW4 definition (default is all OFF) 1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit SET TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 ON √ √ √ √ √ √ √ √ OFF × × × × × × × × Notice: When the SW1-1 is OFF (unframed mode) the TS1 to TS31 is invalid.
Raisecom Technology Co., Ltd OFF Disable To make local timeslot follow remote timeslot, below three conditions should be ensured: (1) This series device is used point to point in pair. (2) There is no PCM device which occupy the Sa bit linked in E1 line. (3) Local device works on slave clock mode.
Raisecom Technology Co., Ltd synchronization WAN interface is passing when this device is connected and its RX CLK is Positive. RX CLK is Positive: Data will be sent to RD signal during RX CLK falling edge. RX CLK RD RX CLK is Reverse: Data will be sent to RD signal during RX CLK rising edge. RX CLK RD Notice: The relationship of TX CLK and TD phase of this series device is auto-adjusted, so users need not to configure it. 5.
Raisecom Technology Co., Ltd Please keep OFF when the device works normally. 4.3.3. Function Dip-switch (SW6) Set ON OFF 1st bit 2nd bit 3rd bit 4th bit Fault Pass Enable Disable Reserved Reserved Reserved 5th bit 6th bit 7th bit Configuration of vendor 8th bit Forbidden to be changed by users Normal Normal Normal 1.
Raisecom Technology Co., Ltd 4.4. Relationship of Dip-switch Configuration and Software Configuration The relationship of dip-switch configuration and software management ability is shown in below table: Dip-switch Whether the software can change dip-switches’ configuration or not SW1~SW4 Can SW5 Can SW6 Can Not 4.5. Basic Connection Type The connection topologies introduced in this part is only for user reference.
Raisecom Technology Co., Ltd local V.35 interface modem ‘Terminal Clock Mode’, and remote V.35 interface modem ‘Slave Clock Mode’. In “Terminal Clock-Slave Clock” topology, if DXC, MUX devices are in E1 link, the DXC, MUX and remote V.35 interface modem should all be slave clock mode (follow the clock of E1 link). Terminal Clock Slave Clock Fiber RC802-30BFV35 RC801-30BFV35 V.35 DTE wire V.35 DTE wire Router Router Clock Source 4.5.3.
Raisecom Technology Co., Ltd 5. Installation & Preparation 5.1. Before installation Please make sure that your V.35 cable matches the equipment you want to connect Please check whether the equipment has been destroyed If you do not use network management, please configure the device through DIP-switch before installation. 5.2. Cautions before Applying the Power Supply It is strictly forbidden to hot-swap the V.35 interface cable.
Raisecom Technology Co., Ltd 6. F & Q If there is any problem during installation and operation, please try the following solutions. If the problems still cannot be solved, please contact distributors for technical support. Power/Error code test indicator (PWR/PAT) is not on Answer: Power supply fails. Check whether the power supply of chassis is working properly.
Raisecom Technology Co., Ltd Compatibility Answer: The optical interface of this equipment deploys PDH technology, so the optical interface can only communicate with Raisecom RC800 series optical modem. But if the remote site is E1 interface fiber optic modem, the E1 interface can communicate with all the other venders’ equipments. Compatibility of V.35 interface Answer: RC800-30B-FV35 series can work with other Raisecom V.
Raisecom Technology Co., Ltd Appendix A: Introduction of Cable Making 1. CBL-V35-M34M/M34F-D Cable making Instruction This cable is used to extend V.35 cable if the DET cable is not long enough. Converter DCE Router DTE CBL-V35-M34M/M34F-D User DTE cable When you order this cable from Raisecom or our agency please make sure the length you want. If you want to make the cable by yourself please refer to below table: ISO2593Male(M34M) V.
Raisecom Technology Co., Ltd device. When using this cable if the clock source is provided by node equipment the RC802-30B-FV35 series device should be configured to V.35 terminal mode. If the clock is provided by fiber optic modem, the node equipment’s clock should be slave mode. Converter DCE CBL-V35-M34M/M34M-X-D User DTE Cable Node Equipment DCE When you order this cable from Raisecom or our agency please make sure the length you want.
Raisecom Technology Co., Ltd BROADBAND to RAISECOM @2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification.