User manual

SW1 SW2 SW3 SW4 SW5 SW6
3.2.1. Setup of Timeslot Dip-switch (SW1 to SW4)
Timeslot switches are SW1, SW2, SW3, SW4
” indicates enable; “×” indicates disable
SW1 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET Frame Status TS1 TS2 TS3 TS4 TS5 TS6 TS7
ON Fractional
OFF Unframed × × × × × × ×
SW2 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET TS8 TS9 TS10 TS11 TS12 TS13 TS14 TS15
ON
OFF × × × × × × × ×
SW3 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET TS16 TS17 TS18 TS19 TS20 TS21 TS22 TS23
ON
OFF × × × × × × × ×
SW4 definition (default is all OFF)
1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit
SET TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31
ON
OFF × × × × × × × ×
Notice:
When the SW1-1 is OFF (unframed mode) the TS1 to TS31 is invalid.
When the SW1-1 is ON( Fractional mode) the TS1 to TS31 is valid and can not be all