Specifications

ENGLISH RAISmanualforRaisRiva
9
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutisnot
suitableforusingforthecompletechimney.Thechimneyandconnectingfluepipemust
haveaminimumdiameterof150mmanditsdimensionshouldbenotlessthanthesizeof
theoutletsocketofthestove.
Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.
90°bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthewallsof
fireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthepresenceof
combustiblematerialsdueaccountmustbetakenoftheguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
Ifitisfoundthatthereisexcessivedraughtinthechimneythenadraughtstabilisershould
befitted.Fittingofadraughtstabiliserwillaffecttherequirementforthepermanentair
supplyintotheroominwhichthestoveisfittedinaccordancewithApprovedDocumentJ
(seealsocombustionairsupply).
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovidedfor
sweepingthechimneyandconnectingfluepipewhereitisnotintendedforthechimneyto
besweptthroughtheappliance,alsotopermitvisualchecksontheintegrityoftheflue
whentheapplianceisserviced.
Hearth
Thehearthshouldbeabletoaccommodatetheweightofthestoveanditschimneyifthe
chimneyisnotindependentlysupported.Theweightofthestoveisindicatedinthe
brochure.
Thestoveshouldalwaysbeinstalledonanoncombustibl ehearthofasizeand
constructionthatisinaccordancewiththeprovisionsofthecurrentBuildingRegulations
ApprovedDocumentJ.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
If the stove is to be installed on a combustible floor surface, it must be covered with a
noncombustible material at least 12mm thick, in accordance with Building Regulations
ApprovedDocumentJ,toadistanceof30cminfrontofthestoveand15cmtoeachside
measuringfromthedoorofthecombustionchamber.