Specifications

ENGLISH RAISmanualforRaisRiva
18
Installationdistancetocombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledis
flammable,youshouldcontactyourbuildingcontractororthelocalbuilding
authorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimney
mustbeindependentlysupportedbywallbracketsoraceilingsupportplate.The
weightofthestoveisindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustibl ehearthofasizeand
constructionthatisinaccordancewiththeprovisionsofthecurrentUKBuilding
RegulationsApprovedDocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwitha
noncombustiblematerialatleast12mmthick,inaccordancewithUKBuilding
RegulationsApprovedDocumentJ,toadistanceof300mminfrontofthestove
and150mmtoeachsidemeasuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthe
hearthandwallsadjacenttothehearthshouldcomplywiththeguidanceonthe
separationofcombustiblematerialgiveninUKBuildingRegulationsApproved
DocumentJandalsointhesestoveinstructions.
Informtheuserthattheappliancehasbeencommissionedandreadytouseand
giveinstructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedto
keeptheminasafeplace.