Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,in
ordertoensurepropercombustion.Notethatanymechanicalexhaustventilation
e.g.anextractionhoodmayreducetheairsupply.Anyairgrillesmustbeplaced
insuchamanner,thattheairsupplyisnotblocked.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,as
wellastheweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshould
considertheheatdistributiontotheotherrooms.Thiswillenableyoutogetthebest
useoutofyourstove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
Commissioningandhandover
Ensureloosepartsarefittedinaccordancewiththeinstructionsgiveninthe
instructionbooklet.
Oncompletionoftheinstallationallowasuitableperiodoftimeforanyfirecement
andmortartodryout,whenasmallfiremaybelitandcheckedtoensurethe
smokeandfumesaretakenfromthestoveupthechimneyandemittedsafelyto
atmosphere.Donotrunatfulloutputforatleast24hours.
Oncompletionoftheinstallationandcommissioningensurethattheoperating
instructionsforthestoveareleftwiththecustomer.Ensuretoadvisethecustomer
onthecorrectuseoftheappliancewiththefuelslikelytobeusedonthestoveand
warnthemtouseonlytherecommendedfuelsforthestove.
Advisetheuserwhattodoshouldsmokeorfumesbeemittedfromthestove.The
customershouldbewarnedtouseafireguardtoBS8423:2002(ReplacesBS
6539)inthepresenceofchildren,agedand/orinfirmpersons.