Specifications
21
Theappliancemustbeservicedandmaintainedusingpartsapprovedbythe
manufacturer,toachievetheproperperformanceoftheappliance.
9. Interruptionofoperation
9.1.Smokespillagearoundthedoor
Itcouldbeduetoolowdraughtinthechimney<12Pa.
Checkwhethertheflueorchimneyisblocked
Checkwhethertheextractionhoodisswitchedon.Ifitis,switchitoffandopena
windowordoorintheproximityofthestoveforashortwhile.
9.2Sootonglass
Itcouldbecausedbytoowetfirewood.
Makesurethatthestoveisheatedproperlywhenfiringup,priortoclosingthedoor.
9.3Stoveisburningtoostrong
Itcouldbecausedby:
Leakaroundthedoorseal
Chimneydraughtistoolarge>22Pa;draughtregulatorshouldbeinstalled
9.4Stoveisburningtooweakly
Itcouldbecausedby:
Toosmallamountoffirewood
Toolittleairsupplyforroomventilation
Uncleansmokechannels
Leakychimney
Leakagebetweenchimneyandflue
Ifthestovecontinuestomalfunction,werecommendthatyoucontactyourRAISdistributor
oryouchimneysweep.
Warning!
Incaseofachimneyfire:
Shutoffallairsupplyfromoutside(ifinstalled)tothestove
Contactthefiredepartment
Neverattempttoputoutthefirewithwater!
Afterwards,youshouldaskyourchimneysweeptocheckthestoveandchimney