Specifications

ENGLISH RAISmanualforRaisAvant
14
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
yous houldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisionsofthecurrentUKBuildingRegulationsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustibl e
materialatleast12mmthick,inaccordancewithUKBui ldingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
and wall sadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.