Specifications

ENGLISH RAISmanualforRais2:1
28
Problemsolving
Smokespillagearounddoor:
couldbeduetotoolowdraughtinthechimney<12P a
 checkiftheflueorchimneyisblocked
 checkifaextractionhoodisswitchedon;ifitis,switchitoffandopenawindow/doorin
theproximityofthestoveforashortwhile.
Sootonglass:
 couldbebecausethefirewoodistoowet.
 makesurethatthestoveisheatedproperlywhenfiringup,priortoclosingthedoor
 couldbebecausethedamperregulationistoolow.
Astoveburningtoostrongcouldbecause dby:
 aleakaroundthedoorseal
 chimneydraughttoolarge>22Pa,draughtcontrolregulatorshouldbeinstalled.
Astoveburningtooweaklycouldbecausedby:
 toolittlefirewood
 toolittleairsupplyfortheroomventilation
 dirtysmokechannels
 leakingchimney
 leakagebetweenchimneyandflue
Ifyourstovecontinuestomalfunction,werecommendthatyoucontactyourRAIS
distributororchimneysweep.
IMPORTANT!!
Toensuresafeburningtheremustbeclearyellowflamesorclearembersatalltimes.The
firewoodshouldnotbesmouldering.Thereforeyoushouldnevercompletelycutofftheair
supply.
WARNING !!
Incaseofchimneyfire:
 shutoffallairsupplyonthewoodburningstove
 contactthefireservices
 neverattempttoputoutfirewithwater!
 afterwards,youshouldaskyourchimneysweeptocheckthestoveandchimney