Rainsoft Division of Aquion, Inc 2080 East Lunt Avenue Elk Grove Village, Illinois, 60007 1.847.437.9400 or 1.800.860.7638 www.rainsoft.com ™ This product is manufactured in an ISO 9001: 2008 certified facility. Model Ultrefiner II - FMV - BNFP, Ultrefiner II - FMV - BNFV, Ultrefiner II - FMV - CHFP and Ultrefiner II - FMV CHFV are tested and certified by NSF International against NSF/ANSI standard 58 for the reduction of claims specified on the performance data sheet.
Congratulations on your purchase of one of the finest Drinking Water Systems available to homeowners. This Owner’s Manual is designed to assist with the operation, maintenance, and installation of the Ultrefiner II System. It is our sincere hope that this manual is clear, concise, and helpful to you as a new owner. Questions? If you have any questions regarding the installation, operation or servicing of this system, please contact your local RainSoft Dealer.
Product Information Figure 1 Your RainSoft Ultrefiner II system provides several stages of treatment to provide you with the best possible drinking water. The components of the system are: Pre-Filter OUTLET TREATED WATER TO FAUCET The pre-filter is a combination carbon/sediment filter. It removes most suspended solids 10 microns or larger in size and also reduces incoming chlorine levels.
Product Certification Information Models ULTREFINER II-FMV-BNFP, ULTREFINER II-FMV-BNFV, ULTREFINER II-FMV-CHFP and ULTREFINER II-FMV-CHFV conform to NSF/ANSI 58 for the specific performance claims as verified and substantiated by test data. See performance data sheets for specific reduction claims. Models ULTREFINER II-FMV-BNFP, ULTREFINER II-FMV-BNFV, ULTREFINER II-FMV-CHFP and ULTREFINER II-FMV-CHFV conform to NSF/ANSI 53 for VOC reduction.
Operational Specifications Working Pressure 40 psi _ 100 psi (275 kPa _ 689 kPa) Operating Temperatures 50°F _ 100°F (10°C _ 38°C) pH Range 2 _ 11 Maximum TDS Level 1400 parts per million (PPM) ! Maximum Turbidity Influent Level 11 NTU (nephelometric turbidity units) Important Note: If the hardness is greater than 5 grains, the system will still perform properly, but the longevity of the membrane may be affected.
Items Required for Installation Tools: Drill, drill bits, Screwdriver, tube cutter, adjustable wrench, Phillips Offset Screwdriver, and vinyl gloves . Parts not included in package: Inlet shut off valve, PTFE Thread Sealant Tape, 1/4 inch O.D. tubing, ! Important Notes: The tubing used for installation must be of food grade type. John Guest or Parker brand tubing is recommended for their compatibility with the fittings on your system. additional 3/8 inch O.D. tubing and mounting screws.
Installation Instructions 1. Install the Filters and Membrane Cartridge • Wearing sterile gloves, remove the two filters and membrane from the sterile packaging and place them in the appropriate housings. Helpful Tip: Be careful not to contaminate the filters and membrane by touching non-sterile objects.
Helpful Tip: The proper drill bit should be selected according to the type of material at the desired installation location. 2. Mount the System Use screws (not supplied) to secure the Ultrefiner II bracket assembly to the Figure 6 USING PHILIPS OFFSET SCREWDRIVER TO SECURE THE ULTREFINER II E TH UM VE IM ABO IN ) M IRED M .4 U IT 9C 25 (8. REQ I UN N( I IN CE 0I . 3.5 TAN INER 0 S 1 DI TREF UL ) CM UM W IM IN LO ) M BE CM ED .0 UIR OLES 3 (3 EQ H IN CE R ING .0 13 TAN UNT S DI E MO TH Figure 7 15.
Figure 8 A PUSH TUBE STRAIGHT PAST O-RING TILL TUBE STOPS TUBE CORRECTLY LOCATED IN SECURED POSITION PUSH IN COLLET TO RELEASE TUBE TUBING CONNECTION PORT TUBE INSERTION DISTANCE(A) UF II INLET - 1/4" TUBE 3/4" UF II DRAIN - 1/4" TUBE 3/4" UFII TANK - 3/8" TUBE -DOUBLE O-RING 1" UF II OUTLET - 3/8" TUBE -DOUBLE O-RING 15/16" STORAGE TANK JG - 3/8" TUBE 3/4" FAUCET FITTING - 3/8" TUBE 3/4" 4. Install the Faucet • Select a location for the faucet to be mounted.
Figure 9 Wrap PTFE Thread Sealant Tape Around 3/8-NPT Tank Thread ! 7.Connect the Drain Outlet Use 1/4 inch tubing (not supplied) to connect the drain outlet to the appropriate drain connection. 8. Secure the Connections Attach the red locking clips (supplied) to the connection fittings. Figure 10 USE RELEASABLE USE RELEASEABLE STRAP TO BAND STRAPS TO BAND TUBING TOGETHER TOGETHER TUBING 10 Important Note: The drain connection must conform to state and local plumbing codes.
9. After SYSTEM START UP Because the Ultrefiner II bracket assembly and cover are reversible, the cover is designed with removable side panels for tube routing. Choose the correct side panel to remove based on the installation. • Remove the side panel by cutting with knife or clippers. • Place cover onto Ultrefiner II and ensure tubing is correctly secure to the one side of the Ultrefiner II bracket assembly.
System Start Up 1. Turn on the Water Supply Allow the system to start filling with water. 2. Fast Flush the System Open the Ultrefiner II faucet and turn the drain barrel to the fast flush (“F” on the drain barrel)position (see figure 12). Figure 12 3. Reposition the Drain Barrel Once the air has been purged from the system, position the drain barrel in #2 service position(see figure 13). The storage tank will continue to fill with water.
7. Complete the Installation • If a 24 hour-flush pre-installation is not performed by your local dealer, it is important to open the faucet and let the system run to drain for 24 hours first. • After the 24 hour water flush , close the Ultrefiner II faucet and allow the storage tank to fill with water. When the storage tank is full, the system will be ready for operation.
How to Change the Filters 1. Turn off the cold water supply to the Ultrefiner II system. 2. Close the storage tank shut-off valve and then open the Ultrefiner II faucet. 3. Place a drip pan or bucket if necessary to catch the water from the filter canisters to prevent spillage. 4. To replace the filters, use a Slim Line Spanner Wrench (not supplied) to unscrew the filter housings from the cap (see figures 14). ! Important Note: When Unscrewing Filter Housings use of Slim Line Spanner Wrench is required.
Ultrefiner II System Exploded View and Parts List 13 11 8 7 23 12 2 1 6 4 14 5 3 9 15 16 5 19 10 4 17 20 6 22 21 18 9 9 10 29 10 30 31 26 24 28 27 25 15
Parts List Item # PART # Quantity 1 51570 1 Description UF II UNIBODY 1/4 DRAIN & 3/8 TANK ASSEMBLY 2 51571 1 UF II SUMP CAP 1/4 INLET PRE ASSEMBLY 3 51572 1 UF II SUMP CAP 3/8 OUTLET POST ASSEMBLY 4 51561 2 UF II WASHER UNIBODY 5 19914 2 O-RING -013 6 19621 2 3/8 O-RING 7 71497 4 SCREW #10-16 x 1in (15-222) 8 51567 6 SCREW 8-16 X 3/4 SS PAN HEAD 9 12994 3 237 O-RING -9516 10 51605 3 UF II SUMP, SLIM LINE GRAY SPECKLES 11 12632 1 029 O-RING 12 17360 1 UNIBOD
1 Hole Dimension with use of air gap 15 Min Ø 16 " Max Ø 1" Air Gap OUT " Tube to Drain Connection 3 8 Air Gap IN Tube to UF II Drain Connection 1 4" 2 Item # 1 2 17 QTY Aquion Part Description 51609 CONTEMP PLUS B-NICKEL FAUCET ASSY ( INCLUDES ITEM # 2) 51624 CONTEMP PLUS CHROME FAUCET ASSY ( INCLUDES ITEM # 2) 51616 CONTEMPORARY FAUCET B-NICKEL ASSY ( INCLUDES ITEM # 2) 51603 CONTEMPORARY FAUCET CHROME ASSY ( INCLUDES ITEM # 2) 51617 FAUCET FITTING 3/8 X 7/16-24 UNS O-RING * 1 1 *
Troubleshooting Guide Symptom No Water Running from Outlet Extremely low Water pressure from outlet or faucet. Drain Water not shutting off after 2 to 3 hours of running. Cause Solution 1. Water Supply Is Turned Off. 1. Turn on the Water. 2. Water Supply Is Blocked 2. Clear Blockage. If this does not work Blockage could be internal to the Ultrefiner II or external with the water line. Contact your Rainsoft Dealer for issues with the Ultrefiner II. 3. Membrane cartridge is Fouled 3.
PERFORMANCE DATA SHEET - page 1 of 3 Ultrefiner II - FMV PREMIUM DRINKING WATER SYSTEM • • • • • • • • • AUTOMATIC DRAIN SHUT-OFF VALVE • pH RANGE: 2 - 11 MANUAL FAST FLUSH VALVE • REPLACEMENT FILTERS: DAILY PRODUCTION RATE = 16.02 GPD DESCRIPTION ITEM# EFFICIENCY RATING3 = 17.54% PRE FILTER 51635 RECOVERY RATING4 = 37.
PERFORMANCE DATA SHEET - page 2 of 3 Ultrefiner II - FMV PREMIUM DRINKING WATER SYSTEM VOC, Standard 53 Reduction Claims 5 CONTAMINANT INFLUENT CHALLENGE MAXIMUM PERMISSIBLE CONCENTRATION PRODUCT WATER mg/L CONCENTRATION mg/L USEPA MCL (MG/L) ALACHLOR 0.050 0.001 0.002 ATRAZINE 0.100 0.003 0.003 BENZENE 0.081 0.001 0.005 CARBOFURAN 0.190 0.001 0.04 CARBON TETRACHLORIDE 0.078 0.0018 0.005 CHLOROBENZENE 0.077 0.001 0.1 CHLOROPICRIN 0.015 0.0002 -------- 2,4-D 0.110 0.0017 0.
PERFORMANCE DATA SHEET - page 3 of 3 Ultrefiner II - FMV PREMIUM DRINKING WATER SYSTEM ARSENIC FACTS Arsenic (As) is a naturally occurring contaminant found in many ground waters. It generally occurs in two forms (valences or oxidation states): pentavalent arsenic (also know as As(V), As(+5), or arsenate) and trivalent arsenic (also know as As(III), As(+3), or arsenite). In natural ground water, arsenic may exist as trivalent arsenic, pentavalent arsenic or a combination of both.
Limited Lifetime Warranty For as long as you own the equipment RainSoft Division of Aquion, Inc. believing its ULTREFINER II PREMIUM DRINKING WATER SYSTEM to be of exceptional quality, hereby warrants said equipment to its first purchaser at retail as follows: THE STORAGE TANK HOUSING, FILTER HOUSING, MEMBRANE HOUSING, CONTEMPORARY FAUCET, CONTEMPORARY PLUS FAUCET ASSY AND UNIBODY CONTROL ARE WARRANTED AGAINST DEFECTS IN MANUFACTURE FOR THE LIFETIME OF THE FIRST PURCHASER AT RETAIL.
Installer Specification Sheet Dealer Name: Phone Number: Installation Number: Installation Date: Model Number: Serial Number: (See Label) Line Pressure: (psi) Hardness: Chlorine: pH: Inlet TDS: 23
™ RainSoft Division of Aquion, Inc. 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 Main Switchboard: 1.847.437.9400 Customer Service: 1.800.860.7638 www.rainsoft.com ©2013 RAINSOFT DIVISION OF AQUION, INC.
Rainsoft Division of Aquion, Inc 2080 East Lunt Avenue ELK Grove Village, Illinois, 60007 1.847.437.9400 or 1800.860.7638 www.rainsoft.com Sistema de Agua Potable Premium Tomando la preocupación fuera del agua Desde 1953 Este producto es fabricado en una instalación certificada por ISO 9001: 2008.
Felicitaciones por su compra de uno de los mejores Sistemas de Agua Potable disponibles para los consumidores. Este Manual del Usuario está diseñado para ayudarlo en el funcionamiento, manutención y instalación del sistema Ultrefiner II. Es nuestro sincero deseo que este manual sea claro, conciso y útil para usted como nuevo usuario.
Información sobre el producto Figura 1 Su sistema Rainsoft Ultrefiner II proporciona varias etapas de tratamiento para proporcionarle la mejor agua potable posible. Los componentes del sistema son: ENTRADA DE AGUA NO TRATADA Prefiltro PARA SISTEMA SALIDA DE AGUA El prefiltro es un filtro de combinación de carbono/sedimentos. Elimina la mayoría de los sólidos suspendidos, 10 micras o mayores, y también reduce los niveles de entrada de cloro.
Información sobre la certificación del producto Los modelos ULTREFINER II - FMV - BNFP, ULTREFINER II - FMV - BNFV, ULTREFINER II - FMV - CHFP y ULTREFINER II - FMV CHFV están conformes a la norma NSF / ANSI 58 para las afirmaciones específicas de rendimiento verificadas y sustentadas en datos de prueba. Consultar las hojas de datos de rendimiento para las afirmaciones específicas de reducción.
Especificaciones de operación Presión de funcionamiento 40 psi – 100 psi (275 kPa – 689 kPa) ! Nota Importante: Si la dureza es mayor que 5 granos, el sistema seguirá funcionando correctamente, pero la longevidad de la membrana puede verse afectada. * Los índices de eficiencia y de recuperación son verificadas mediante pruebas en conformidad con la norma NSF / ANSI 58.
Elementos necesarios para la instalación ! Herramientas: Taladro, brocas, destornillador, cortador de tubo, llave inglesa ajustable, destornillador acodado Phillips y guantes de vinilo. Notas importantes: La tubería usada para la instalación debe ser de grado alimenticio. Los tubos John Guest o de marca Parker son recomendados debido a su compatibilidad con los accesorios de su sistema. Partes no proveídas en el paquete : Válvula de cierre de entrada, cinta de teflón, tubería de 1/4 pulgadas D. I.
Instrucciones de instalación 1•Instalar los filtros y el cartucho filtrante Consejo útil: Tener cuidado de no contaminar los filtros y la membrana al tocar objetos no esterilizados. •Usando guantes estériles, retirar los dos filtros y la membrana del envase estéril y colocarlos en las carcasas apropiadas.
2. Montar el sistema • Utilizar tornillos (no proveidos) para fijar el conjunto de soportes Ultrefiner II a la ubicación prevista. Consejo útil: La broca apropiada debe ser seleccionada de acuerdo con el tipo de material en el lugar de instalación deseado. Figura 6 L PU DE .5 A E 3 NID A D LA U D I ER DE U A ) Q RE CIM cm MA R EN .4 NI MI ) PO (25 A M I L C C PU AN (8.9 II. ST .
4. Instalar la válvula de cierre de entrada (no proveída) • Cerrar el suministro de agua fría y abrir el grifo de agua fría para aliviar cualquier presión de línea; • Instalar la válvula de cierre de entrada (no proveída) entre la válvula de cierre existente y el grifo de cocina, de manera que cumpla con los códigos de plomería estatales y locales; • Usar tubería de 1/4 pulgadas (no proveída) para conectar la entrada de la válvula de cierre a la entrada del sistema.
8. Después del ARRANQUE DEL SISTEMA Cómo el conjunto de soportes Ultrefiner II y la tapa son reversibles, la tapa está diseñada con paneles laterales extraíbles para el enrutamiento de la tubería. Elegir el panel lateral correcto para quitar con base en la instalación. • Quitar el panel lateral. Usando cuchillo o tijeras. • Colocar la tapa sobre el Ultrefiner II y asegurar que la tubería está bien segura a un lado del conjunto de soportes Ultrefiner II.
Arranque del sistema 1. Abrir el suministro de agua Dejar que el sistema comience a llenar con agua. 2. Enjaguar rápidamente el sistema Abrir el grifo Ultrefiner II y girar el cilindro de drenaje para la posición de descarga rápida ("F" en el cilindro de drenaje) (ver figura 12).. Figura 12 Consejos útiles: Tanto en la posición de descarga rápida como en la posición #2, las tuercas del cilindro de drenaje están alineadas con los tornillos de montaje.
7. Terminar la instalación • Si una descarga de 24 horas de preinstalación no es llevada a cabo por su distribuidor local, es importante abrir el grifo y dejar que el sistema funcione para drenar durante 24 horas. • Después de la descarga de agua 24 horas, cerrar el grifo Ultrefiner II y permitir que el tanque de almacenamiento se llene de agua. Cuando el tanque de almacenamiento esté lleno, el sistema estará listo para uso.
Cómo cambiar los filtros ! 1.Cerrar el suministro de agua fría al sistema Ultrefiner II. Nota importante: Al desenroscar las carcasas de los filtros usar la llave de filtros Slim Line. Desenroscar las carcasas de los filtros usando otras herramientas no autorizadas puede dañar las carcasas de los filtros y anular la garantía. 2. Cerrar la válvula de cierre del tanque de almacenamiento y abrir el grifo Ultrefiner II. 3.
Vista despiezada del sistema Ultrefiner II y lista de piezas 13 11 8 7 23 12 2 1 6 4 14 5 3 9 15 16 5 19 10 4 17 20 6 22 21 18 9 9 10 29 10 30 31 26 24 28 27 25 38
Lista de Piezas Ítem # Pieza # Cantidad 1 51570 1 Descripción CONJUNTO DESAGÜE 1/4 & TANQUE 3/8 UF II 2 51571 1 CONJUNTO DE ENTRADA TAPA DE CONTENEDOR 1/4 UF II 3 51572 1 CONJUNTO SALIDA TAPA DE CONTENEDOR 3/8 4 51561 2 ARANDELA UF II 5 19914 2 JUNTA TÓRICA -013 6 19621 2 JUNTA TÓRICA 3/8 7 71497 4 TORNILLO #10-16 x 1 pulg.
Vista Despiezada del Grifo y Lista de Piezas 1 Dimension del Agujero con boquete de aire 15 " Min Ø 16 Max Ø 1" SALIDA de Boquete de Aire Tubo de 3/8" para Conexion de Drenaje 2 Ítem # Cant. 51624 1 51603 40 Descripción CONJ. GRIFO CONTEMP PLUS B-NICKEL PLUS CHROME (incluye ítem # 2) CONJ. GRIFO CONTEMP (incluye ítem # 2) 1 51616 2 ENTRADA del Boquete de Aire Tubo de 1/4" para Conexion de Drenaje UF II Pieza Aquion 51609 ENTRADA de Agua Producida con Tubo de 3/8" 1 51617 CONJ.
Guía de resolución de problemas Síntoma No hay agua corriendo de la salida Presión del agua proveniente de la salida o del grifo extremadamente baja. El agua de drenaje no cierra después de 2 a 3 horas de funcionamiento Causa Solución 1. El suministro de agua está cerrado. 1. Abrir el agua. 2. El suministro de agua está bloqueado. 2. Eliminar la obstrucción. Si esto no funcione, la obstrucción puede ser interna a el Ultrefiner II o externa, en la tubería del agua.
HOJA DE DATOS DE RENDIMIENTO - página 1 de 3 Ultrefiner II - FMV Sistema de Agua Potable Premium • • • • • • • • • VÁLVULA DE CIERRE DE DRENAJE AUTOMÁTICA • RANGO pH: 2 – 11 VÁLVULA DE DESCARGA RÁPIDA MANUAL • FILTROS DE REPUESTO: ÍNDICE DE PRODUCCIÓN DIARIA = 16.02 GPD DESCRIPCIÓN ÍTEM: 3 ÍNDICE DE EFICIENCIA =17.54% PREFILTRO 51635 ÍNDICE DE RECUPERACIÓN = 37.
HOJA DE DATOS DE RENDIMIENTO - página 2 de 3 Ultrefiner II - SFMV Sistema de Agua Potable Premium COV, Declaraciones de reducción – Norma 535 1. Estos sistemas han sido probados para el tratamiento de agua CONCENTRACIÓN MEDIA AFLUENTE MG/L CONCENTRACIÓN MÁXIMA ADMISIBLE EN EL AGUA PRODUCIDA (MG/L) LCM APE EE. UU. (MG/L) ALACLOR 0.050 0.001 0.002 ATRAZINA 0.100 0.003 0.003 menos. Este sistema redujo el arsénico pentavalente, pero puede BENCENO 0.081 0.001 0.
HOJA DE DATOS DE RENDIMIENTO - página 3 de 3 Ultrefiner II - FMV Sistema de Agua Potable Premium HECHOS ACERCA DE ARSÉNICO El arsénico (As) es un contaminante natural encontrado en aguas distintas. Por lo general, se produce en dos formas (valencias o estados de oxidación): arsénico pentavalente (también conocido como As(V), As (+5) o arseniato) y arsénico trivalente (también conocido como As(III), As(+3), o arsenito).
Garantía limitada de por vida Durante el tiempo que usted posee los equipos RainSoft Division de Aquion, Inc.
Ficha técnica del Instalador Nombre del distribuidor: Número de teléfono: Número de la instalación: Fecha de instalación: Número de modelo: Número de serie: (ver etiqueta) Presión de línea: : Dureza:: Cloro: pH: TSD de entrada: 46 (psi)
NOTAS 47
™ RainSoft Division of Aquion, Inc. 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 Principal panel de control: 1.847.437.9400 Servicio al Cliente: 1.800.860.7638 www.rainsoft.com ©2013 RAINSOFT DIVISION OF AQUION, INC.