RainSoft Division of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 1.847.437.9400 or 1.800.860.7638 www.rainsoft.com Part No.
Table of Contents Introduction................................................................................................ 3-4 Application Limitations .................................................................................5 Operational Specifications ........................................................................5-6 Product Certification Information.............................................................. 6 Installation Instructions ...........................................
Congratulations on your purchase of a RainSoft Centurion system. This Owner’s Manual is designed to assist with the operation, maintenance, and installation of the system. It is our sincere hope that this manual is clear, concise, and helpful to you as a new owner. Questions? If you have any questions regarding the installation, operation, or servicing of this system, please contact your local RainSoft Dealer.
A note to the homeowner Your Centurion system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of RainSoft Centurion. Sinks and fixtures - should have little or no spotting. If water is allowed to evaporate off a surface, small spots may be left behind. This spotting should not require any more than a wet cloth or sponge to remove.
Application Limitations • Ferrous Iron: 0.3mg/L Max • Manganese: 0.05mg/L Max • Copper: 1.3mg/L Max Iron and Manganese: Just as with conventional water softening media, RainSoft Centurion needs to be protected from excess levels of certain metals that can easily coat the active surface, reducing its effectiveness over time. Public water supplies rarely, if ever, present a problem, but if the water supply is from a private well confirm that the levels of iron (Fe) and manganese (Mn) are less than 0.
• This system must be installed in accordance with all applicable state and local laws and regulations. • This system must be installed in an area not affected by extreme heat, cold, or the elements. The selected installation area must be adequate for easy service and accessibility. • The installation must be on a cold water supply.
Installation Instructions continued from page 6. 1. Safety Precautions • To prevent accidents and/or injuries, do not hoist the equipment over your shoulder; use a hand truck. • Do not lay the system on its side. • Wear safety glasses and work gloves during installation and service. 2.
Installation Instructions continued from page 7. 6. Install the Pipe Connector (Yoke) to the Bypass Valve Important Note: Because of UP-flow operation, the correct flow direction is the opposite of the arrows on the bypass valve. • Connect the raw water pipe to the inlet pipe connection of the yoke. See Figure 1 for the correct direction of flow. The arrow molded into bypass valve will indicate the opposite side direction because it is set up as UP-flow operation.
Carbon Filter Anti-Scale IN e n Li UT O e Lin System Start Up 1. Turn on the Water and Check for Leaks • Close all faucets that were opened in Step 5 of the Installation Instructions. • Turn the water back on at the meter or pressure tank. • Check for leaks. If a leak is present, drain the plumbing again before soldering. 2. Flush the System • Open a cold water faucet and allow water to run for a few minutes or until all foreign material from the installation is washed out; close the faucet.
Exploded View 4 5 6 3 10
Parts List ITEM 1 2 QUANTITY 1 1 PART NUMBER 14587 14597 51504 51506 DESCRIPTION TANK WITH BASE Centurion 844 H Centurion 1054 H RISER PIPE ASSEMBLY Centurion 844 H Centurion 1054 H TANK COLLAR Centurion 844 H 3 1 19777 19778 Centurion 1054 H 4 1 19574 COMPOSITE QRS HEAD 5 1 19245 QRS BYPASS ADAPTER 6 1 17557 BYPASS ASSEMBLY 11
Troubleshooting Guide Symptom Cause Solution 1. Poor water quality 1. The raw water has changed. 2. The filter media may be exhausted. 1. Call your RainSoft Dealer for a new water analysis. 2. Call your RainSoft Dealer to replace the filter media (part number 51501). 2. Loss of water pressure 1. Low pressure to the system. 1. Bypass the system to confirm the problem. • If the problem still exists after bypass, it is not related to the RainSoft equipment. Have your water distribution system checked.
Limited Lifetime Warranty For as long as you own the equipment RainSoft Division of Aquion Water Treatment Products, believing its RAINSOFT CENTURION to be of exceptional quality, hereby warrants said equipment to its first purchaser at retail as follows: THE TREATMENT TANK AND VALVE ARE WARRANTED AGAINST DEFECTS IN MANUFACTURE FOR THE LIFETIME OF THE FIRST PURCHASER AT RETAIL. THE FILTER MEDIA IS NOT WARRANTED. THE FILTER MEDIA SERVICE LIFE IS DEPENDENT ON SPECIFIC WATER CONDITIONS AND USAGE.
NOTES 14
NOTES 15
RainSoft Division of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 Main Switchboard: 1.847.437.9400 Customer Service: 1.800.860.7638 www.rainsoft.