Instructions / Assembly

Installation
Mount Enclosure
Select a location for the installation of the Rainpal controller
Mount RAINPAL to the wall with the appropriate mounting hardware for specific wall surface.
Take off the six screws in the front and remove the cover.
Connect Line Power
Thread supplied power cord through the smaller weatherproof port at the bottom of the enclosure.
Wire the line power cord to the three pin connector at location “AC IN”.
The plug is detachable from the board for easy access (Figure 1).
Caution! Installing the wires incorrectly could damage the unit
General Arrangement and Reference Points
Figure 1
Connecting Zone Wiring
Route zone wires through large weatherproof gland at the bottom of the enclosure.
Attach one line from each irrigation valve, light, or water feature relay to the appropriate
receptacle in the 13 pin male plug (supplied).
CAUTION! The 24 Vac output is designed only for activation of irrigation valve
solenoids and relays. DO NOT power lights and accessories directly with the output from
the unit.
The common ground connection on the 13-pin plug is furthest to the right.
Attach the output for a Boost Pump relay (if installed) to Zone 12.
2
Large Port
Small Port
Black
White
Green
110Vac Top = Black; Center = White; Bottom = Green
220Vac Top = Black; Center = White; Bottom = Green
Mounting
Holes
Zone Wiring
Rain Sensor
Flow Sensor
Ethernet Port
Three Pin
Power Connector
Serial and Wireless
connection