Installation guide
Using the FlashCONNECT Socket Server Manager
FlashCONNECT Administrator’s Guide 67
Fatal Errors
Fatal errors result in a dropped connection. The client must be reconnected to the
FCSocket Server. The following fatal errors are generated and displayed (if you
select this option) in the FCSocket Server Manager.
• Unknown Protocol. The message does not start with a recognized protocol
header.
• Client unexpectedly closes the connection.
• I/O error when sending or receiving a message from the client.
Viewing Monitor Information
The FlashCONNECT Socket Server information may be displayed in the lower pane of
the FlashCONNECT Socket Server Manager dialog box and/or from the log file
location you designated depending on the Log Options set. See Using the
FlashCONNECT Socket Server Log for information about setting log options.
The following shows the FlashCONNECT Socket Server Manager with error, access
and detail log information recorded in the lower panel.
Incorrect w3Exec,
w3SessionId
007 Either both a w3Exec and w3SessionId were
specified or neither w3Exec or w3SessionId
were specified.
Unsupported Feature 008 Feature used is not supported, for example,
an unsupported data type.
Maximum Message
Length Exceeded
009 Overall message length exceeds the
maximum message length.
Closing Page Sent 010 Application used w3ClosingPage to terminate
an application which isn’t supported in
mvDesigner.
Change Account Failed 011 Account password in the w3Apps file is not
correct.
Error Name Value Definition