Error 1067
If starting the FlashCONNECT server on the Web server host produces this error, shut
down and restart the server.
Unable to attach to shared memory segment.
Please refer to the diagnostic message Unable to connect to FCService in
Diagnostic Messages Displayed On the Browser
.
Failed to open semaphore
There is a version mismatch between fccgi.exe and FCService. The versions must
match. Reinstalling both the D3 and Windows components may be necessary. To
determine the version of fccgi.exe and FCService refer to the topic Determining
Release Levels. (Entering -V from MS-DOS no longer performs this function.)
Sorry no FlashCONNECT servers are available at this time
Try again in a few moments. There are no available FlashCONNECT connections.
Possible causes:
• There are no connections started.
• No phantoms are available.
• No database licenses are available.
• They are all in use.
ERROR - Missing required elements in form
This message displays if the URL starting a FlashCONNECT application is missing
either a w3Exec parameter or a w3SessionId parameter. This also happens if the
calls to w3HtmlFormBeg or w3HtmlFormEnd are missed.
This URL shows the error:
http://w3lib.rainingdata.com/cgi-bin/fccgi.exe?w3ClosingPage=!url