Installation guide

Troubleshooting for Windows
FlashCONNECT Administrator’s Guide 175
Test 6. Verify that the FCService is running.
Test 7. Confirm the fccgi.exe program can access the
FCService program.
Setup: FlashCONNECT must be installed on the Web server.
Process: From the command prompt, enter these commands:
cd path
fcdebug -h
where:
path is the location where FlashCONNECT is installed.
Success: FlashCONNECT header information displays. A description of the
header information is located in Using the FlashCONNECT Server
Debug Program.
Failure: FlashCONNECT not running message displays.
Follow-up: The following options are available from the Services program
(accessed from the Control Panel):
If the FCService is not running, start FCService.
If the FCService is already running, stop FCService. Restart
FCService again.
Stop the Web server and FCService. Restart the Web server and
FCService.
Stop the database, the Web server and FCService. Restart the
database, the Web server and FCService.
Setup: FCService must be running on the Web server.
Process: From the MS-DOS command prompt in the directory that contains
fcdebug, enter:
fcdebug -h
Success: FCService configuration displays.
Failure: An error message displays.
Follow-up: See the following sections:
Using the FlashCONNECT Server Debug Program
Diagnostic Messages Displayed On the Browser