Instruction Manual
W9864G2GH
- 12 -
8. TABLE OF OPERATING MODES
Fully synchronous operations are performed to latch the commands at the positive edges of CLK.
Table 1 shows the truth table for the operation commands.
TABLE 1 TRUTH TABLE (NOTE (1), (2))
COMMAND DEVICE
STATE
CKEN-1 CKEN DQM BS0, 1 A10 A0-A9
CS
RAS CAS
WE
Bank Active Idle H x x v v V L L H H
Bank Precharge Any H x x v L x L L H L
Precharge All Any H x x x H x L L H L
Write Active (3) H x x v L v L H L L
Write with Autoprecharge Active (3) H x x v H v L H L L
Read Active (3) H x x v L v L H L H
Read with Autoprecharge Active (3) H x x v H v L H L H
Mode Register Set Idle H x x v v v L L L L
No-Operation Any H x x x x x L H H H
Burst Stop Active (4) H x x x x x L H H L
Device Deselect Any H x x x x x H x x x
Auto-Refresh Idle H H x x x x L L L H
Self-Refresh Entry Idle H L x x x x L L L H
Self Refresh Exit idle
(S.R)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
x
x
Clock suspend Mode Entry Active H L x x x x x x x x
Power Down Mode Entry Idle
Active (5)
H
H
L
L
x
x
x
x
x
x
x
x
H
L
x
H
x
H
X
H
Clock Suspend Mode Exit Active L H x x x x x x x X
Power Down Mode Exit Any
(power
down)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
X
H
Data write/Output Enable Active H x L x x x x x x x
Data Write/Output Disable Active H x H x x x x x x x
Notes:
(1) v = valid, x = Don’t care, L = Low Level, H = High Level
(2) CKEn signal is input leve l when commands are provided.
(3) These are state of bank designated by BS0, BS1 signals.
(4) Device state is full page burst operation.
(5) Power Down Mode can not be entered in the burst cycle.
When this command asserts in the burst cycle, device state is clock suspend mode.