Instruction Manual
Preliminary W79E8213/W79E8213R Data Sheet 
Publication Release Date: July 11, 2008 
- 62 -  Revision A2 
Figure 13-1: Timer/Counters 0 & 1 in Mode 0 
13.1.3 Mode 1 
Mode 1 is similar to Mode 0 except that the counting register forms a 16-bit counter, rather than a 13-
bit counter. This means that all the bits of THx and TLx are used. Roll-over occurs when the timer 
moves from a count of FFFFh to 0000h. The timer overflow flag TFx of the relevant timer is set and if 
enabled an interrupt will occur. The selection of the time-base in the timer mode is similar to that in 
Mode 0. The gate function operates similarly to that in Mode 0. 
Figure 13-2: Timer/Counters 0 & 1 in Mode 1 