Manual
W25Q80, W25Q16, W25Q32
- 50 -
11.7 AC Electrical Characteristics
SPEC
DESCRIPTION SYMBOL ALT
MIN TYP MAX
UNIT
Clock frequency
for all instructions, except Read Data (03h)
2.7V-3.6V VCC & Industrial Temperature
F
R
f
C
D.C. 80 MHz
Clock freq. Read Data instruction (03h) fR D.C. 50 MHz
Clock High, Low Time except Read Data (03h) tCLH,
t
CLL
(1)
6/7 ns
Clock High, Low Time for Read Data (03h)
instruction
tCRLH,
t
CRLL
(1)
8 ns
Clock Rise Time peak to peak tCLCH
(2)
0.1 V/ns
Clock Fall Time peak to peak tCHCL
(2)
0.1 V/ns
/CS Active Setup Time relative to CLK tSLCH tCSS 5 ns
/CS Not Active Hold Time relative to CLK tCHSL 5 ns
Data In Setup Time tDVCH tDSU 2 ns
Data In Hold Time tCHDX tDH 5 ns
/CS Active Hold Time relative to CLK tCHSH 5 ns
/CS Not Active Setup Time relative to CLK tSHCH 5 ns
/CS Deselect Time ( for Read instructions / Write,
Erase and Program instructions)
tSHSL tCSH 10/50 ns
Output Disable Time tSHQZ
(2)
tDIS 7 ns
Clock Low to Output Valid
2.7V-3.6V / 3.0V-3.6V
t
CLQV tV 7 / 6 ns
Output Hold Time tCLQX tHO 0 ns
/HOLD Active Setup Time relative to CLK tHLCH 5 ns
Continued – next page