Manual
21
U3742BM
4735A–RKE–11/03
Table 7. Effect of the Configuration Word Sleep
Table 8. Effect of the Configuration Word XSleep
Table 9. Effect of the Configuration Word Lim_min
Sleep
Start Value for Sleep Counter
(T
Sleep
= Sleep × Xsleep × 1024 × T
Clk
)Sleep4 Sleep3 Sleep2 Sleep1 Sleep0
000000 (Receiver is continuously polling until a valid signal occurs)
000011 (T
Sleep
» 2ms for XSleep = 1 in US/European applications)
00010 2
00011 3
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0101111 (USA: T
Sleep
= 22.96 ms, Europe: T
Sleep
= 23.31 ms) (Default)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
11101 29
11110 30
11111 31 (Permanent sleep mode)
XSleep
Extension Factor for Sleep Time (T
Sleep
= Sleep × Xsleep × 1024 × T
Clk
)XSleep
Std
XSleep
Temp
0 0 1 (Default)
0 1 8 (XSleep is reset to 1 if bit check fails once)
1 0 8 (XSleep is set permanently)
1 1 8 (XSleep is set permanently)
Lim_min Lower Limit Value for Bit Check
Lim_min < 10 is not applicable (T
Lim_min
= Lim_min × XLim × T
Clk
)
001010 10
001011 11
001100 12
001101 13
001110
14 (Default)
(USA: T
Lim_min
= 228 µs, Europe: T
Lim_min
= 232 µs)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
111101 61
111110 62
111111 63