User guide
22
TS81102G0
2105C–BDC–11/03
Explanation of
Test Levels
Notes: 1. The level 1 and 2 tests are performed at 50 MHz.
2. Only MIN and MAX values are guaranteed (typical values are issuing from characterization
results).
Table 6. Explanation of Test Levels
Num Characteristics
1 100% production tested at +25
°C.
(1)
2 100% production tested at +25°C, and sample tested at specified temperatures.
(1)
3 Sample tested only at specified temperatures.
4
Parameter is guaranteed by design and characterization testing (thermal steady-state
conditions at specified temperature).
5 Parameter is a typical value only.