User Manual

2
TH7841A
1998AIMAGE05/02
T
Operating Range Operating range defines the temperature limits between which the functionality is guar-
anteed: 0°Cto70°C.
Operating
Precautions
Shorting the video output to V
SS
to V
DD
, even temporarily, can permanently damage the
output amplifier.
Absolute Maximum Ratings*
Storage Temperature ..................................... -55°Cto+150°C
*NOTICE: Stresses above those listed under ABSOLUTE
MAXIMUM RATINGS may cause permanent
device failure. Functionality at or above these
limits is not implied. Exposure to absolute maxi-
mum ratings for extended periods may affect
device reliability.
Operating Temperature........................................0°Cto+70°C
Thermal Cycling..........................................................15°C/mn
Maximum Voltages:
Pins: 3, 5, 9, 10, 11, 13,
16, 19, 20, 21, 25, 27........................................-0.3V to +18V
Pins: 12. 18 ......................................................-0.3V to +16V
Pins: 14, 15, 28 ................................................................. 0V