DC/DC Clock The DC/DC block needs a clock with a 50% duty cycle. The frequency must also respect
a value between 3.68 MHz and 4 MHz. The first requirement imposes a divider in the
clock path and the second constraint is solved with the use of a prescaler.
Figure 13. Functional Block Diagram
Clock Control Register This register is used to reload the clock prescaler of the DC/DC converter clock.
Table 11. DCCKPS Register
DCCKPS - DC/DC converter Reload Register (BFh)
Reset Value = XXXX XX11b
Clock Prescaler Before supplying the DC/DC block, the oscillator clock is divided by a factor 2 to 5 to
adapt the clock needed by the DC/DC converter. This factor is controlled with the
DCCKPS register.
The prescaler factor must be chosen to match the requirement range which is 4MHz.
Table 12. Examples of Factors
1
F
CLK_DC/DC
F
OSC
F
OSC
2 to 5
(2 to 5)
DCCKPS
Address BFh
76543210
- - - - - - DCCKPS DCCKPS
Bit
Number
Bit
Mnemonic Description
7:2 -
Reserved
Do not use write those bits
1:0 DCCKPS
Clock Reload Register
Prescaler value
00b: Division factor equals 2
01b: division factor equals 3
10b: division factor equals 4
11b: division factor equals 5 (reset value which minimize the consumption)
XTAL (MHz) DCCKPS Value
Prescaler
Factor DC/DC Converter CLK (MHz)
800h2 4
12 01h 3 4
14.756 02h 4 3.689
16 02h 4 4
20 03h 5 4