Manual

RFM01
Version: 1.2 Date: 10/17/2008
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com
• Stand by current less than 0.3uA
Typical Application
• Remote control
• Remote sensor
• Wireless data collection
• Home security system
• Toys
• Tire pressure monitoring system
Pin Definition
SMD DIP
definition Type Function
VDI DO Valid data indicator
VDD S Positive power supply
SDI DI SPI data input
SCK DI SPI clock input
nSEL DI Chip select (active low)
FFIT/SDO DO FIFO fill interrupt(active low) or status read data output
nRES DO
Reset outputactive low
GND S Power ground
nIRQ DO
Interrupts request outputactive low
DATA/nFFS DO/DI Data input(non FIFO mode)/ FIFO select
DCLK/CFIL/FFIT
DO/AIO/DO
Clock output (no FIFO )/ external filter capacitor(analog mode)/ FIFO
interrupts(active high)when FIFO level set to 1, FIFO empty
interruption can be achieved
CLK DO Clock output for external microcontroller