User Manual
RF01
16 VDD_LN S Positive supply voltage
17 VDD _A S Analog VDD(connect to VDD)
18 VDD_D S Digital VDD(connect to VDD)
19 ARSSI AO Analog RSSI output
20 VDI DO Valid Data Indicator output
Typical Application
GENERAL DEVICE SPECIFICATION
All voltages are referenced to V
ss
, the potential on the ground reference pin VSS.
Absolute Maximum Ratings (non-operating)
Symbol Parameter Min Max Units
V
dd
Positive supply voltage -0.5 6.0 V
V
in
Voltage on any pin -0.5 V
dd
+0.5 V
I
in
Input current into any pin except VDD and VSS -25 25 mA
ESD Electrostatic discharge with human body model 1000 V
T
st
Storage temperature -55 125
℃
Recommended Operating Range
Symbol Parameter Min Max Units
V
dd
Positive supply voltage 2.2 5.4 V
Top Ambient operating temperature -40 85
℃
Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: sales@hoperf.com http://www.hoperf.com