Owner manual



RC1180-MBUS
2008 Radiocrafts AS RC1180-MBUS Data Sheet (rev. 1.0) Page 18 of 28
Reserved 0x17 0x00 (0)
Reserved 0x18 0x00 (0)
MAN_ID1 Manufacturer
ID, first byte
0x19 0x00-0xFF
(0-255)
0x0C (12)
MAN_ID2 Manufacturer
ID, second byte
0x1A 0x00-0xFF
(0-255)
0xAE
(174)
ID1 Unique ID, first
byte
0x1B 0x00-0xFF
(0-255)
0x12 (18)
ID2
Unique ID,
second byte
0x1C 0x00-0xFF
(0-255)
0x34 (52)
ID3
Unique ID, third
byte
0x1D 0x00-0xFF
(0-255)
0x56 (86)
ID4
Unique ID, forth
byte
0x1E 0x00-0xFF
(0-255)
0x78
(120)
VER
Version 0x1F 0x00-0xFF
(0-255)
0x01 (1)
DEV
Device 0x20 0x00-0xFF
(0-255)
0x07 (7)
Reserved 0x21 0x01 (1)
Reserved 0x22 0x01 (1)
Reserved
0x23 0x00 (0)
Reserved
0x24 0x00 (0)
Reserved
0x24 0x00 (0)
Reserved
0x26 0x00 (0)
Reserved 0x27 0x04 (4)
Reserved 0x28 0xFF
(255)
Reserved 0x29 0x08 (8)
Reserved
0x2A 0x00 (0)
Reserved
0x2B 0x00 (0)
Reserved
0x2C 0x00 (0)
Reserved
0x2D 0x00 (0)
Reserved
0x2E 0x00 (0)
Reserved
0x2F 0x00 (0)
Data and configuration interface, UART Serial Port
UART_BAUD_RATE Baud rate 0x30 0x00: Not used
0x01: 2400
0x02: 4800
0x03: 9600
0x04. 14400
0x05: 19200
0x06: 38400
0x07: 76800
0x08: 153600
0x09: 155600
0x05 (5) BE CAREFUL
IFCHANGING AS HOST
MAY LOOSE CONTACT
WITH MODULE!
Does not take effect until
module is re-booted /
reset.
Reserved
0x31 0x08 (8)
Reserved
0x32 0x00 (0)
Reserved
0x33 0x01 (1)
Reserved
0x34 0x05 (5)
UART_FLOW_CTRL UART flow
control
0x35 0: None
1:CTS only
3:CTS/RTS
4:RXTX(RS485)
0x00 (0)
DATA_INTERFACE Data interface 0x36 0x00: MBUS
packet with ID
and address
0x01: Application
data only
0x00 (0) Sets receiver data format.
First byte is always
packet length
Reserved 0x37 0x01 (1)
Reserved
0x38 0x2B (43)
Reserved
0x39 0x00 (0)
Reserved
0x3A 0x01 (1)
Exit from memory
configuration
0xFF No argument
should be sent
To exit from command
mode the ‘X’ command
must be sent after ‘>’ is
received.