Note : Ask for a bearer Note : Bearer supported
AT+CBST?
Note : Current values
+CBST:7,0,1
OK
Note : Command valid
AT+CBST=81,0,0
Note : Ask for a bearer
+CME ERROR : 4
Note : Bearer not supported
Defined values :
<speed>
0 (default): Autobauding (modem type : none)
1: 300 bps (modem type: V.21)
2: 1200 bps (modem type: V.22)
3: 1200/75 bps (modem type: V.23)
4: 2400 bps (modem type: V.22bis)
5: 2400 bps (modem type: V.26ter)
6: 4800 bps (modem type: V.32)
7: 9600 bps (modem type: V.32)
8: Specific
12: 9600 bps (modem type: V.34)
14(*): 1400 bps (modem type : V.34)
65: 300 bps (modem type: V.110)
66: 1200 bps (modem type: V.110)
68: 2400 bps (modem type: V.110)
70: 4800 bps (modem type: V.110)
71: 9600 bps (modem type: V.110)
75(*): 14400 bps (modem type: V.110)
(*)This speed configures data and fax 14.4 kbps bearers.
<name>
No data compression is provided and only asynchronous modem is supported :
<name> = 0.
<ce> : Connection element
0: Transparent only
1(default) : Non transparent only
2: Transparent preferred
3: Non transparent preferred