ELECTRICAL CHARACTERISTICS (continued)
(V
IN1
= V
IN2
= 3.6V, V
AGND
= V
PGND
= 0V, V
DD
= 1.8V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
=
+25°C.) (Note 2)
PARAMETER CONDITIONS MIN TYP MAX UNITS
Minimum Duty Cycle
Forced PWM mode only, minimum duty cycle in
(OPERATION_MODE_ = 1) = 0%
16 %
Maximum Duty Cycle 60 %
Minimum On- and Off-Time 30 40 50 ns
OUT Discharge Resistance During shutdown or UVLO, from SNS+ to PGND 650 Ω
SNS+, SNS- Input Impedance 400 600 850 kΩ
Time Delay from PWM
to Power-Save Mode
Time required for error amplifier to stabilize before
switching mode
70 µs
Time Delay from Power-Save
Mode to PWM
Time required for error amplifier to stabilize before
switching mode
140 µs
SYNCHRONIZATION (SYNC)
SYNC = 00 default 18.9 26.0 38.0
SYNC = 1X default 14.2 19.2 28.5SYNC Capture Range
SYNC = 01 default 9.5 13.0 19.0
MHz
SYNC Pulse Width 13 ns
PROTECTION CIRCUITS
Thermal-Shutdown Hysteresis 20 °C
Thermal Shutdown +160 °C
Note 2: All devices are 100% production tested at T
A
= +25°C. Limits over the operating temperature range are guaranteed by
design.