The  MAX4998/MAX14998  high-speed  passive  switches 
route  one  DisplayPort  source  between  two  possible 
destinations or  vice  versa. The  MAX4998  is used  to 
switch two-lanes plus  AUX/HPD DisplayPort, and  the 
MAX14998  is  used  to  switch  four-lanes  plus  AUX/HPD 
DisplayPort.
The  MAX4998/MAX14998  feature  two  digital  control 
inputs (SEL1, SEL2) to switch signal paths.
Digital Control Inputs (SEL1, SEL2)
The  MAX4998/MAX14998  provide  two  digital  control 
inputs  (SEL1,  SEL2)  to  select  the  signal  path  between 
the  COM_  and  NO_/NC_  channels.  SEL1  selects  high-
frequency  switching,  while  SEL2  selects  AUX/HPD.  On 
the  MAX4998,  switches  1  and  2  are  high-frequency 
switches and switches  3 and 4  are both low-frequency 
switches. On the MAX14998, switches 1, 2, 3, and 4 are 
high-frequency switches and switches 5 and 6 are low-
frequency  switches.  The  truth  tables  for  the  MAX4998/
MAX14998  are depicted  in  the  Functional  Diagrams/
Truth Tables. Drive SEL_ 0V to  V
DD
 to minimize power 
consumption.
Analog Signal Levels
The  MAX4998/MAX14998  accept  standard  DisplayPort 
signals  to  a  maximum  of  (V
DD
  -  1.8V).  Signals  on  the 
COM_+ channels are routed to either the NO_+ or NC_+ 
channels.  Signals  on  the  COM_- channels  are  routed 
to either the NO_- or  NC_- channels. The MAX4998/
MAX14998  are  bidirectional  switches,  allowing  COM_, 
NO_, and NC_, to be used as either inputs or outputs.
                  Pin Description (continued)
PIN
NAME FUNCTION
MAX4998 MAX14998
23 34 NO0+ Analog Switch 1. Normally Open positive terminal.
24 — GND Ground
25 39 NC1- Analog Switch 2. Normally Closed negative terminal.
26 40 NC1+ Analog Switch 2. Normally Closed positive terminal.
27 41 NC0- Analog Switch 1. Normally Closed negative terminal.
28 42 NC0+ Analog Switch 1. Normally Closed positive terminal.
— 10 COM3- Analog Switch 4. Common negative terminal.
— 11 COM4+ Analog Switch 5. Common positive terminal.
— 12 COM4- Analog Switch 5. Common negative terminal.
— 14 COM5+ Analog Switch 6. Common positive terminal.
— 15 COM5- Analog Switch 6. Common negative terminal.
— 18 NO5- Analog Switch 6. Normally open negative terminal.
— 19 NO5+ Analog Switch 6. Normally open positive terminal.
— 20 NO4- Analog Switch 5. Normally open negative terminal.
— 21 NO4+ Analog Switch 5. Normally open positive terminal.
— 22 NC5- Analog Switch 6. Normally Closed negative terminal.
— 23 NC5+ Analog Switch 6. Normally Closed positive terminal.
— 24 NC4- Analog Switch 5. Normally Closed negative terminal.
— 25 NC4+ Analog Switch 5. Normally Closed positive terminal.
— 27 NO3- Analog Switch 4. Normally Open negative terminal.
— 35 NC3- Analog Switch 4. Normally Closed negative terminal.
— — EP
Exposed Pad. Internally connected to GND. Connect to a large plane to maximize 
thermal performance. Not intended as an electrical part.