User Manual

HD44780U
52
AC Characteristics (V
CC
= 4.5 to 5.5 V, T
a
= –30 to +75°C*
3
)
Clock Characteristics
Item Symbol Min Typ Max Unit Test Condition Notes*
External External clock frequency f
cp
125 250 350 kHz 11
clock
External clock duty Duty 45 50 55 % 11
operation
External clock rise time t
rcp
0.2 µs11
External clock fall time t
fcp
0.2 µs11
R
f
oscillation
Clock oscillation frequency f
OSC
190 270 350 kHz R
f
= 91 k
V
CC
= 5.0 V
12
Note: * Refer to the Electrical Characteristics Notes section following these tables.
Bus Timing Characteristics
Write Operation
Item Symbol Min Typ Max Unit Test Condition
Enable cycle time t
cycE
500 ns Figure 25
Enable pulse width (high level) PW
EH
230
Enable rise/fall time t
Er
, t
Ef
——20
Address set-up time (RS, R/W to E) t
AS
40
Address hold time t
AH
10
Data set-up time t
DSW
80
Data hold time t
H
10
Read Operation
Item Symbol Min Typ Max Unit Test Condition
Enable cycle time t
cycE
500 ns Figure 26
Enable pulse width (high level) PW
EH
230
Enable rise/fall time t
Er
, t
Ef
——20
Address set-up time (RS, R/W to E) t
AS
40
Address hold time t
AH
10
Data delay time t
DDR
160
Data hold time t
DHR
5—