3.5.7 Custom AT Commands
3.5.7.1 General Configuration AT Commands
3.5.7.1.1 Network Selection Menu Availability - +PACSP
+PACSP - Network Selection Menu Availability SELINT 2
AT+PACSP?
Read command returns the current value of the <mode> parameter in the
format:
+PACSP<mode>
where:
<mode> - PLMN mode bit (in CSP file on the SIM)
0 - restriction of menu option for manual PLMN selection.
1 - no restriction of menu option for Manual PLMN selection.
AT+PACSP=?
Test command returns the OK result code.
Note The command is available only if the ENS functionality has been previously
enabled (see #ENS)
3.5.7.1.2 Manufacturer Identification - #CGMI
#CGMI - Manufacturer Identification SELINT 0 / 1
AT#CGMI
Execution command returns the device manufacturer identification code
with command echo. The output depends on the choice made through
#SELINT command.
AT#CGMI?
Read command has the same effect as the Execution command
#CGMI - Manufacturer Identification SELINT 2
AT#CGMI
Execution command returns the device manufacturer identification code with
command echo. The output depends on the choice made through #SELINT
command.
AT#CGMI=?
Test command returns the OK result code.
3.5.7.1.3 Model Identification - #CGMM
#CGMM - Model Identification SELINT 0 / 1
AT#CGMM
Execution command returns the device model identification code with
command echo.
AT#CGMM?
Read command has the same effect as the Execution command
#CGMM - Model Identification SELINT 2
AT#CGMM
Execution command returns the device model identification code with
command echo.