Owner manual
Telit GE864 and GC864 Product Description
80273ST10008a Rev. 14 - 18/09/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 12 of 62
2.3.3 RoHS compliance
As a part of Telit corporate policy regarding environmental protection, the GE864 and GC864 comply
with the RoHS (Restriction of Hazardous Substances) directive of the European Union (EU Directive
2002/95/EG).
2.4 Operating Frequency
The operating frequencies in GSM, DCS, PCS modes are conform to the GSM specifications.
Mode Freq. TX (MHz) Freq. RX (MHz) Channels (ARFC) TX - RX offset
850 824.2÷848.8 869.2÷893.8 0 ÷ 124 45 MHz
890.0 - 914.8 935.0 - 959.8 0 – 124 45 MHz
E-GSM-900
880.2 - 889.8 925.2 - 934.8 975 - 1023 45 MHz
DCS-1800 1710.2 - 1784.8 1805.2 - 1879.8 512 – 885 95 MHz
PCS-1900 1850.2 - 1909.8 1930.2 - 1989.8 512 - 810 80 MHz
2.5 Transmitter output power
GSM–850/900
The Telit GE864 and GC864 transceiver modules in GSM–850/900 operating mode are class 4 in
accordance with the specifications which determine the nominal 2W peak RF power (+33dBm) on 50
Ohm.
DCS–1800/PCS–1900
The Telit GE864 and GC864 transceiver modules in DCS–1800/PCS–1900 operating mode are class 1
in accordance with the specifications which determine the nominal 1W peak RF power (+30dBm) on
50 Ohm.
2.6 Reference sensitivity
GSM–850/900
The sensitivity of the Telit GE864 and GC864 modules according to the specifications for the class 4
GSM 850/900 portable terminals are –107 dBm typical in normal operating conditions.
DCS–1800/PCS–1900
The sensitivity of the Telit GE864 and GC864 module according to the specifications for the class 1
portable terminals DCS-1800/PCS 1900 are –106 dBm typical in normal operating conditions.