Owner manual
Telit GE864 and GC864 Product Description
80273ST10008a Rev. 14 - 18/09/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 11 of 62
2.2 Weight
weight
GE864 6 gr
GC864 6,1 gr
2.3 Environmental requirements
The Telit GE864 and GC864 modules are compliant with the applicable ETSI reference documentation
GSM 05.05 Release1998.
2.3.1 Temperature range
GE864-QUAD /
GE864-PY
GC864-QUAD /
GC864-PY
Note
–20°C ÷ +55°C –20°C ÷ +55°C
The module is fully functional(*) in all
the temperature range, and it fully
meets the ETSI specifications.
Operating
Temperature
Range
–40°C ÷ +85°C –40°C ÷ +85°C
The module is fully functional (*) in all
the temperature range. Temperatures
outside the range –20°C ÷ +55°C,
might slightly deviate from ETSI
specifications.
Storage and Non
Operating
Temperature Range
–40°C ÷ +85°C –40°C ÷ +85°C
(*) Functional: the module is able to make and receive voice calls, data calls, SMS and make GPRS traffic.
2.3.2 Vibration Test (non functional)
• 10 ÷12Hz ASD = 1.92m 2 /s 3
• 12 ÷ 150Hz –3dB/oct