3.2.1.1 Restrictions
Only basic option and UIH framing is supported.
Only convergence layers type 1 and 3 are supported.
Autobauding is not compatible with multiplex mode. It is neither possible to
start multiplexing when autobauding is active (AT+IPR=0), nor to set
autobauding during multiplex mode, since the multiplexer uses only a fixed
baud rate. In the same way, the bit rate can not be changed through AT+IPR
command while multiplex mode is active. Therefore, AT+IPR=<rate> should
not be used, and will have no effect.
Before starting multiplexing mode, port speed must be configured by
AT+IPR=<rate> command, to be compliant with defined values for <port
_speed> parameter (in the volume 1, refer to "Multiplexing Mode +CMUX"
section, "Parameters and Defined Values" section).
3.2.1.2 Specific Behaviors
In multiplexing mode, AT configuration commands (as AT+CMEE for example),
(see: [2]§ 1.10) will be applied to all logical channels.
In multiplexing mode, unsolicited result code (see: [2]§ 1.7) will be transmitted
to all logical channels
AT commands are grouped by classes (SMS, phonebook, GPRS, SIM TOOL
KIT, … See [2] §3.7.1) and launching an AT command from a port, has for the
effect to lock all commands belonging to the same class.
If another port launches an AT command of the locked class, an +CME ERROR:
536 will occur as long as the class is not released (at first command’s
completion time).
If Bluetooth is started, it is not possible to start CMUX on UART2.
In the same way, it MUX is started on UART2, it is not possible to start
Bluetooth.
After an
at+cfun=1
during a CMUX session, CMUX is automatically restarted
by the Wireless CPU
®
with previous parameters, and all previous opened DLCs
are reopened, with the speed of
at+ipr?
Command.
DCD, RI and DTR signals are managed virtually:
When V24 sets DCD,RI or DTR signal, a MSC frame is sent to remote part, to
indicate a virtual state change .Everything is logical, no physical signals are
involved.
+++ Escape Sequence is always possible to get offline.
Flow control is managed physically or virtually by MSC.
By default, the Wireless CPU
®
manage a hardware flow control on a UART, and
this flow control becomes virtual on logical channels when some DLCs are
opened.
At CMUX session stop, Wavecom the Wireless CPU
®
automatically goes back into AT
mode, without having to reset the Wireless CPU
®
.
Two timeouts are implemented for CMUX connection: