• With application binary
AT+WOPEN=1
OK
AT+wopen=8
+WOPEN: 8,0,0,0
AT+WOPEN=8,0,0,0
OK
AT+CFUN=1
(Press any key, Wireless CPU
®
and Open AT
®
application start normally)
•
With
application binary
AT+WOPEN=1
OK
AT+WOPEN=8,1,10,12
OK
AT+WOPEN=8
+WOPEN: 8,1,10,12
OK
Press the keys 10 and 12, nothing occurs
AT+CFUN=1
OK
Press any keys except key 10 and 12, Wireless CPU
®
and Open AT
®
application start
normally
AT+CFUN=1
OK
Press the keys 10 and 12, Wireless CPU
®
starts but Open AT
®
application does not
start
AT+WOPEN=7
+WOPEN: 7,14
Open AT
®
application starting was cancelled by Open AT
®
Safe Boot
AT+CFUN=1
OK
Don’t press any keys, Wireless CPU
®
and Open AT
®
application start normally