21.10.3 Parameters and Defined Values
<mode>: requested operation
0 stop a specific filter
1 enable a specific filter
2 ask for the current parameters values of a specific filter
<filter>: filter type
1 high pass filter in TX mode
2 high pass filter in RX mode
3 low pass filter in TX mode
4 low pass filter in RX mode
<param
x
>: filter parameters
range high pass filter in
TX and RX mode
(default values)
low pass filter in
TX and RX mode
(default values)
<param1> 0-65535 4032 0
<param2> 0-65535 61562 0
<param3> 0-65535 57484 0
<param4> 0-65535 8051 0
<param5> 0-65535 4032 4096
<param6> 0-65535 0 0
<param7> 0-65535 0 0
<param8> 0-65535 61617 0
<param9> 0-65535 3742 0
<param10>
0-65535 3919 4096
21.10.4 Parameter Storage
The parameters are stored in EEPROM without using the AT&W.command The
default value can be restored using AT&F and "AT+VIP=1".