5.2.4 Parameter storage
The <Mode>, <A&Dsize>, <Key1> and <Key2> parameters are stored in EEPROM
without using the AT&W command. The default value can be restored using AT&F.
5.2.5 Examples
Command Responses
AT+WOPEN=?
+WOPEN: (0-8),(0-1344),(0-24),(0-24)
OK
AT+WOPEN?
+WOPEN: 0
OK
AT+WOPEN=2
Note: Get the Open AT
®
library versions
+WOPEN: 2,"AT v03.01","AT v02.10"
OK
Note: Open AT
®
version 2.10 application downloaded.
AT+WOPEN=7
+WOPEN: 7,0
OK
Note: Open AT
®
application not started
AT+WOPEN=1
+CME ERROR: 541
Note: since main versions do not match, the Open AT
®
application can not be started.
AT+WOPEN=2
Note: Get the Open AT
®
library versions
+WOPEN: 2,"AT v2.00","AT v2.00"
OK
Note: Open AT
®
v2.00 library version. An embedded
application has been downloaded on this product..
AT+WOPEN=3
OK
Note: The flash objects are erased
AT+WOPEN=1
Note: Start the embedded application.
OK
+WIND: 3
Note: Product resets in order to start the embedded
application.