5.2.3 Parameters and Defined Values
<Mode>: operating mode
0 stop the Open AT
®
embedded application
If the Open AT
®
application is running, the Wireless CPU
®
resets.
1 start the Open AT
®
embedded application
If the Open AT
®
application is stopped, the Wireless CPU
®
resets.
2 get the Open AT
®
library versions
3 erase the Open AT
®
embedded application flash objects
4 erase the Open AT
®
embedded application
5 suspend (in Wavecom OS) the Open AT
®
embedded application
tasks
6 If the <A&Dsize> parameter is used: configure the Application &
Data storage size.
If the <A&Dsize> parameter is not used: display the current A&D
storage place size and Open AT
®
application space size.
7 Open AT
®
application current state
8 Configure the Open AT
®
Safe Boot: please refer to the
<SafeBootState>, <Key1> & <Key2> parameters description for
more information
<IntVersion>: ASCII string giving the internal Open AT
®
library version
<ExtVersion>: ASCII string giving the external Open AT
®
library version
If no embedded application is loaded, the <ExtVersion> parameter is
not returned.
<A&DSize>: Kbytes size allocated for the Application & Data storage place
usable only with <Mode> = 6
range: 0–1344 (default value: 768 Kbytes).
Provided parameter value will be rounded up to the nearest flash
sector sub-division (64 Kbytes). For example, if a 100 Kbytes size is
required, a 128 Kbytes size will effectively be set.
<OatSize>: Open AT
®
application reserved size (in Kbytes)
returned with <Mode> = 6
This size is calculated from the <A&Dsize> one, since the whole
available size for Open AT
®
and A&D storage places is 1600 Kbytes
(<OatSize> + <A&Dsize> = 1600).