Data Commands
Radio Link Protocol Parameters +CRLP
©Restricted
Page: 72 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 2 August 23, 2007
13.4.3 Parameters and Defined Values
<iws>: down window size
range: 0-61 (default value: 61)
<mws>: up window size
range: 0-61 (default value: 61)
<T1>: acknowledgement timer in units of 10 ms
range: 40-255 (default value: 48)
<N2>: retransmission attempts
range: 1-255 (default value 6)
<ver>: RLP version number
0 V42bis not supported
1 V42bis supported (default value)
13.4.4 Parameter Storage
Parameters are stored in EEPROM using the AT&W command. The default value can
be restored using AT&F.
13.4.5 Examples
Command Responses
AT+CRLP=?
+CRLP: (0-61),(0-61),(40-255),(1-
255),(0,1)
OK
AT+CRLP=61,61,48,6,0
OK
Note: Set new parameters
AT+CRLP?
+CRLP: 61,61,48,6,0
OK