Manual

Data Commands
Using AT Commands during a data connection
©Restricted
Page: 64 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 2 August 23, 2007
13 Data Commands
13.1 Using AT Commands during a data connection
To use AT commands during a data connection (e.g. while the product is in online
mode), it is necessary to switch to offline mode.
Switch from online to offline mode
To switch from online mode to offline mode, the "+++" sequence must be sent.
Following this, the product gets back to offline mode with an "OK" response,
and a AT command can be sent. This "+++" sequence must be sent with a
guard time of 1s before and after the sequence.
Note:
The "+++" sequence will only work with the +ICF command using one of
the following settings:
o 8 data bits, with no parity
o 7 data bits, with even parity
Switch from offline to online mode
Please refer to the "O" command description.