12.7.3 Parameters and Defined Values
<RelCause>: release cause
range: 1-127
integerl value
Please refer to section "Failure Cause from GSM 04.08
recommendation" in the Appendixes chapter of this guide.
<location>: release location
Please refer to ETSI GSM 24.008 [8] for values.
0 user
1 private network serving the local user
2 transit network
3 transit network
4 public network serving the remote user
5 private network serving the remote user
7 international network
10 network beyond inter-working point
12.7.4 Parameter Storage
None.
12.7.5 Examples
Command Responses
AT+WATH=?
+WATH: (1-127),(0-5,7,10)
OK
AT+WATH=31
Note: Ask for disconnection with release
cause=normal and location=USER
OK
Note: All calls, if any, are released
AT+WATH=17,2
Note: Ask for disconnection with release
cause=user busy and location= public network
serving the local user
OK