Manual

Call Control Commands
Wavecom Hang-up +WATH
©Restricted
Page: 47 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 2 August 23, 2007
12.7 Wavecom Hang-up +WATH
12.7.1 Description
This Wavecom proprietary command is used by the application to disconnect the
remote user, specifying a release cause and the location. In the case of multiple calls,
all calls are released (active, on-hold and waiting calls).
12.7.2 Syntax
Action command
AT+WATH=<RelCause>[,<location>]
OK
Read command
None
Test command
AT+WATH=?
+WATH= (list of supported <RelCause>s),(list of supported
<location>s)