Manual

GSM Network Commands
Wavecom Location +WLOC
©Restricted
Page: 26 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 2 August 23, 2007
11.6.3 Parameters and Defined Values
<mode>: requested operation
0 stop automatic shots
1 one shot requested
2 automatic shots requested (every x seconds)
3 configuration of the <dump> value
<time period>: time period for automatic shots
range: 5-255 (multiple of 5, default value 5)
If omitted, the value will be set to 5.
<requested dump>: requested measurements
bitfield: 1-255 (default value:255)
If omitted, the value will be set to 255.
1 date and time will be returned in the response
2 TA will be returned in the response
4 BCCH will be returned in the response
8 network measurements will be returned in the response
16 CI will be returned in the response
32 LAC will be returned in the response
64 MNC-MCC will be returned in the response
<MCC-MNC>: MCC and MNC codes
3 bytes in hexadecimal format (network coding)
<LAC>: Location Area Code
string type; two byte location area code in hexadecimal format
(e.g. "00C3" equals 195 in decimal)
<CI>:
Cell Id
string type; two bytes in hexadecimal format
If the Cell Id is not available, this parameter is omitted.
<NetMeas>:
network measurements
16 bytes in hexadecimal format