9.4.3 Parameters and Defined Values
<fac>: facility P2 SIM P2
"PS" SIM lock facility with a 8 digits password
"SC" PIN code 1/CHV1
"AO" BAOC (Barr All Outgoing Calls)
"OI" BOIC (Barr Outgoing International Calls)
"OX" BOIC-exHC (Barr Outgoing International Calls except to Home
Country)
"AI" BAIC (Barr All Incoming Calls)
"IR" BIC-Roam (Barr Inc. When Roaming outside Home Country)
"AB" All Barring services
"AG" All out Going barring services
"AC" All inComing barring services
"P2" PIN code 2/CHV2
"FD" SIM Fixed Dialing Numbers (FDN) memory feature (PIN2 is
required as <password>)
"PN" Network lock with a 8 digits password (NCK)
"PU" Network Subset lock with a 8 digits password (NSCK)
"PP" Service Provider lock with a 8 digits password (SPCK).
"PC" Corporate lock with a 8 digits password (CCK)
<oldpwd>: on 4 or up to 8 or 16 digits according to the facility
<newpwd>: new password specified for the facility
string type [….]
<pwdlength>: maximum length of the password for the facility
range: 4-16