Manual

Global Configuration Commands
Wavecom Custom Character Set +WCCS
©Restricted
Page: 97 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 1 August 23, 2007
6.16.3 Parameters and Defined Values
<mode>: requested operation
0 display the table
1 edit the table
<table>: character table selection
0 custom to GSM conversion table (default table is PCCP437
to GSM table)
1 custom alphabet table (default table is GSM 7 bit default
alphabet)
2 custom alphabet extension table (default table is GSM 7 bit
default alphabet extended)
<character_range>: range of character codes in <table>
0-127 for table index 1 and index 2
0-255 for table index 0
<character_number>:
number of displayed characters
0-127 for table index 1 and index 2
0-255 for table index 0
<characters>: sequence of ASCII characters
hexastring type
6.16.4 Parameter Storage
The <characters> parameter is stored in EEPROM without using AT&W.