User guide

DS3134
193 of 203
AC CHARACTERISTICS - LOCAL BUS IN CONFIGURATION MODE (LMS = 1)
(0°C TO +70°C; VDD = 3.0V TO 3.6V)
Parameter Symbol Min Typ Max Units Notes
Set Up Time for LA[15:0] Valid to LCS*
Active
t1 0 ns
Set Up Time for LCS* Active to Either
LRD*, LWR*, or LDS* Active
t2 0 ns
Delay Time from Either LRD* or LDS*
Active to LD[15:0] Valid
t3 120 ns 1
Hold Time from Either LRD*, LWR*, or
LDS* Inactive to LCS* Inactive
t4 0 ns
Hold Time from LCS* Inactive to
LD[15:0] Tri-State
t5 5 20 ns
Wait Time from Either LWR* or LDS*
Active to Latch LD[15:0]
t6 75 ns 1
LD[15:0] Set Up Time to Either LWR* or
LDS* Inactive
t7 40 ns
LD[15:0] Hold Time from Either LWR*
or LDS* Inactive
t8 2 ns
LA[15:0] Hold from Either LWR* or
LDS* Inactive
t9 5 ns