DS2741
Current Monitor and Accumulator with
Integrated Sense Resistor
_______________________________________________________________________________________ 3
TEMPERATURE SENSOR CHARACTERISTICS
(V
CC
= +2.5V to +4.5V, T
A
= -20°C to +70°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS 
Temperature Error          ±5  °C 
AC ELECTRICAL CHARACTERISTICS: I
2
C INTERFACE
(2.5V ≤ V
CC
≤ 4.5V, T
A
= -20°C to +70°C, timing referenced to V
IL(MAX)
and V
IH(MIN)
. See Figure 4.)
PARAMETER SYMBOL  CONDITIONS  MIN TYP MAX UNITS 
SCL Clock Frequency  f
SCL
 (Note 5)  0    400  kHz 
Bus Free Time Between STOP 
and START Conditions 
t
BUF
  1.3      μs 
Hold Time (Repeated) START 
Condition 
t
HD:STA
  0.6      μs 
Low Period of SCL  t
LOW
  1.3      μs 
High Period of SCL  t
HIGH
  0.6    μs 
Data Hold Time  t
HD:DAT
  0    0.9  μs 
Data Setup Time  t
SU:DAT
  100      ns 
START Setup Time  t
SU:STA
  0.6      μs 
SDA and SCL Rise Time  t
R
 (Note 6) 
20 + 
0.1C
B
 300 ns 
SDA and SCL Fall Time  t
F
 (Note 6) 
20 + 
0.1C
B
 300 ns 
STOP Setup Time  t
SU:STO
  0.6      μs 
SDA and SCL Capacitive 
Loading 
C
B
 (Note 6)      400  pF 
Note 1: All voltages are referenced to GND. Currents entering the IC are specified positive and currents exiting the IC are negative.
Note 2: Compensation of the internal sense resistor value for initial tolerance and temperature coefficient of -20°C to +70°C can
reduce the maximum reportable magnitude to 2.5A.
Note 3: Current sampling ceases for 2.5ms every 144ms to allow the ADC to measure temperature.
Note 4: Typical value for t
ERR1
is specified at 3.6V and +25°C, max value is specified for 0°C to +50°C. Max value for t
ERR2
is 
specified for -20°C to +70°C.
Note 5: Interface timing shown is for fast-mode (400kHz) operation. This device is also backward compatible with standard-mode
I
2
C timing.
Note 6: C
B
—Total capacitance of one bus line in pF; timing referenced to 0.1 x V
CC
and 0.9 x V
CC
.